产品介绍
瑞泰 7500kVA 电阻与无功移动式负载箱系统是一款大功率测试解决方案,专为大型发电机组、电力系统、船用柴油发电机、燃气轮发电机和 UPS 系统而设计。
The 系统 delivers 6,000kW of active 电力 and 4,500kvar of reactive 电力, with an adjustable 功率因数 ranging from PF 0.8 to 1.0. It provides independent 控制 of the 电阻 and reactive loads, together with 模块化 forced-风冷 and dual 电力 supplies featuring 自动 fast transfer for the 散热 fans. Equipped with PLC-based 智能控制, the 系统 incorporates comprehensive 防护功能, 包括 temperature, airflow, short-电路, overvoltage, over- and under-频率, insulation, and smoke 防护. Supporting steady-state, transient, step-load, and 自动测试模式s, it can simultaneously acquire, record, and analyze 测试参数 while generating detailed 测试 reports. This provides a 安全, accurate, and traceable 解决方案 for large-scale 电力系统性能 verification.
关键特性与优势
产品规格
| 移动式负载参数 | 系统组成 | 负载柜外壳、高压开关柜、干式变压器、电阻负载、感性负载、数据采集系统、控制系统、散热系统、保护系统 |
| 有功功率 | 6000 kW | |
| 无功功率 | 4500kVAR | |
| 视在功率 | 7500kVA | |
| 负载额定电压 | AC 380V(经变压器降至 380V) | |
| 额定频率 | 50Hz | |
| 负载特性 | 电阻器和电感器集成,电阻器与电抗可分离独立通断。 | |
| 功率因数 | PF = 0.8~1.0 可调 | |
| 负载连接 | 三相四线 | |
| 三相平衡 | 不平衡度 ≤ ±2% | |
| 加载精度 | ≤±2% | |
| 负载步进值 | 10 kW / 7.5 kVAR | |
| 散热方式 | 强制风冷,以风机为核心模块。 | |
| 风机电源 | 两路电源(内外部)自动快速切换。 | |
| 进排风方式 | 侧进风,顶部排风 | |
| 负载温升 | 出风口 1 米处温升 ≤120℃ | |
| 工作方式 | 连续工作 | |
| 负载控制电源 | AC 380V/50Hz | |
| 测量/显示精度 | ±0.5%FS | |
| 绝缘等级 | F | |
| 电阻材料 | 特种合金电阻器 | |
| 负载控制 系统参数 |
控制方式 | 本地/远程 |
| 控制模式 | 手册/自动 | |
| 加载中功能 | 单机控制加载与联合控制加载(可与厂内 AC6.6kV-4200kW-RL 和 AC6.6kV-3000kVA-RL/AC 移动式测试负载并联运行) | |
| 测量与控制功能 | A、V、Hz、kW、COSΦ 采集与显示 | |
| 控制响应时间 | ≤200ms | |
| 负载防护 | 保护机制包括短路、高温、风量控制和紧急停机。 | |
| 运行环境温度 | -20℃ 至 +50℃ | |
| 运行环境湿度 | 50% ~ 95% | |
| 负载柜运行环境与参数 | 工作海拔 | 2000m 及以下 |
| 相对湿度 | ≤95%,无凝露 | |
| 大气压力 | 86-106 kPa | |
| 集装箱尺寸 | 13000mm×2438mm×2896mm(长×宽×高) | |
| 重量 | 每台负载能力约 20 吨。 | |
| 防护等级 | IP54 | |
| 使用地点 | 室外(耐盐雾、沙尘暴、雨雪等) | |
| 安装与运输 | 箱体四角设有承重吊装孔,满足吊装需求。 | |
| 负载扩展 | 1+N 加载箱并联扩展 | |
| 箱体颜色 | 按客户需求 | |
| 应用范围 | 适用于燃气轮发电机组、船用柴油发电机组、陆用柴油发电机组和 UPS 系统。 |